Arcadian Networks Inc. V390I Manuale Utente
58
V290iA User Guide
Issue
Actions
Bad Temperature Sensor event
occurred
occurred
1. Open a Telnet session with the V390i, either locally or
remotely (refer to Telnet Connection to the V390i on
page 33).
page 33).
2. Type the following CLI commands to check which
temperature sensor is malfunctioning:
cd /v/v
get_bist_results
cd /v/v
get_bist_results
3. The following sensors are checked:
Tuner Sensor, CPU Sensor, Cisco Sensor,
Environment Sensor, RTC (Real Time Clock).
View the results of the check on-screen. You should take
action in the following cases:
Environment Sensor, RTC (Real Time Clock).
View the results of the check on-screen. You should take
action in the following cases:
If the CPU temperature sensor is malfunctioning, the
V390i will shut itself down. You must replace the V390i.
V390i will shut itself down. You must replace the V390i.
The Cisco temperature sensor and the Environment
temperature sensor both measure the same thing.
Therefore, the V390i will shut itself down only if both of
them are malfunctioning. If one of these sensors is
malfunctioning, the V390i should be fixed, but it need
not be done immediately.
temperature sensor both measure the same thing.
Therefore, the V390i will shut itself down only if both of
them are malfunctioning. If one of these sensors is
malfunctioning, the V390i should be fixed, but it need
not be done immediately.
A device attached to the V390i
is not operating
is not operating
Ping the V390i Cisco Router IP address.
If the ping is successful, the problem probably lies with
the device.
the device.
If the ping is not successful, ping the IP address of the
V384+A:
V384+A:
If the ping is successful, check the Cisco router IP
configuration.
configuration.
Otherwise, follow the instructions in V390i is not
operational on page 57.
operational on page 57.