58 
V290iA User Guide 
Issue 
Actions 
Bad Temperature Sensor event 
occurred 
 
1.  Open a Telnet session with the V390i, either locally or 
remotely (refer to Telnet Connection to the V390i on 
page 33). 
2.  Type the following CLI commands to check which 
temperature sensor is malfunctioning: 
 
cd /v/v 
get_bist_results
 
3.  The following sensors are checked:  
Tuner Sensor, CPU Sensor, Cisco Sensor, 
Environment Sensor, RTC (Real Time Clock). 
View the results of the check on-screen. You should take 
action in the following cases: 
„ 
If the CPU temperature sensor is malfunctioning, the 
V390i will shut itself down. You must replace the V390i. 
„ 
The Cisco temperature sensor and the Environment 
temperature sensor both measure the same thing. 
Therefore, the V390i will shut itself down only if both of 
them are malfunctioning. If one of these sensors is 
malfunctioning, the V390i should be fixed, but it need 
not be done immediately. 
A device attached to the V390i 
is not operating 
„ 
Ping the V390i Cisco Router IP address. 
„ 
If the ping is successful, the problem probably lies with 
the device. 
„ 
If the ping is not successful, ping the IP address of the 
V384+A: 
„ 
If the ping is successful, check the Cisco router IP 
configuration. 
„ 
Otherwise, follow the instructions in V390i is not 
operational
 on page 57.