5. Trouble Shooting                                                                                             
 
Console 
Problem Checklist 
The POWER LED does 
not activate. 
Check if the power cable is firmly plugged into the EU-200BX and 
power outlet. 
No information is 
displayed during 
console connection. 
① 
Check if the RJ-45 / RS-232 cable is firmly plugged into the 
EU-200BX and PC.     
② 
Check if the selected serial port of the Hyper Terminal 
matches the actual serial port. 
③ 
Check if the configured information such as baud rates, data 
bits, parity, etc. is correct. 
IP Setting 
Problem Checklist 
IP address of the EU-
200BX is not 
configured. 
Check for typos when configuring the IP address. 
Connection is not 
possible to the SEMS 
Software. (Ping is also 
not possible.) 
① 
Connect to the EU-200BX through the console port. 
② 
Check the IP address of the EU-200BX. 
③ 
If the IP address is incorrect, set the appropriate IP address 
to the EU-200BX. Refer to 4.3 Setting the IP of the EU-200BX 
for details. 
④ 
If the IP address is correct, check the RJ-45 cable connected 
to the EU-200BX. 
⑤ 
Perform ping tests from the EU-200BX to the SEMS Software 
installed PC. 
⑥ 
Connect to the EU-200BX using the SEMS Software. 
⑦ 
Go to the EU-200BX main screen and download the previous 
EU information. Refer to the SEMS Software User Guide 3.5.1 
EU-200BX EMS Unit.   
 
If the problem is still not solved, please contact Xeline’s Technical Support Center.