⑥ 
Installation is successful if the following message appears.   
< Reply from Default Gateway IP:  bytes=32  time<xxms  TTL=64 > 
 
Figure 17 Checking the Ping Results 
 
 
4.4 Resetting to Factory Default Mode 
 
Use the reset button at the back of the SU-200BX in order to reset the configuration into 
factory default mode.   
① 
Turn off the power of the SU-200BX. 
② 
Disconnect the RJ-45 cable. 
③ 
Use a long sharp instrument (such as a pin) in order to push down on the reset button. 
④ 
Turn on the SU-200BX while pushing down on the reset button. 
⑤ 
Using the sharp instrument, push down on the reset button for 1 second. Wait at 
least 1 second before repeating the procedure at least 3 times or more. 
⑥ 
The ACT LED will blink when the SU-200BX is changed to the factory default mode. 
⑦ 
Reset the power of the SU-200BX.