Xeline Co. LTd. SU-200BX Manuale Utente
SU-200BX
Installation Manual
This document is subject to change without prior notice.
17
⑥
Installation is successful if the following message appears.
< Reply from Default Gateway IP: bytes=32 time<xxms TTL=64 >
Figure 17 Checking the Ping Results
4.4 Resetting to Factory Default Mode
Use the reset button at the back of the SU-200BX in order to reset the configuration into
factory default mode.
①
Turn off the power of the SU-200BX.
②
Disconnect the RJ-45 cable.
③
Use a long sharp instrument (such as a pin) in order to push down on the reset button.
④
Turn on the SU-200BX while pushing down on the reset button.
⑤
Using the sharp instrument, push down on the reset button for 1 second. Wait at
least 1 second before repeating the procedure at least 3 times or more.
⑥
The ACT LED will blink when the SU-200BX is changed to the factory default mode.
⑦
Reset the power of the SU-200BX.