Aperto Networks PM365-BS Manuale Utente

Pagina di 150
D–6
PacketMax 5000 Installation and Operation Manual,   10007678 Rev J
Chapter D.  System Specifications
4.2.0.1 Operation
Table D-3
Operation Specifications
4.2.0.2 Power Requirements 
AC Option:  100 to 240 V AC, 47 to 63 Hz
DC Option:
-  Recommended Operating Range(1):     
 
-43 to -58 Volts
-  Absolute Maximum Range(2):              -36 to -72 Volts 
Stresses beyond those listed under “absolute maximum ratings” may cause perma-
nent damage to the device. These are stress ratings only, and functional operation of 
the device at these or any other conditions beyond those indicated under “recom-
mended operating conditions” is not implied. Exposure to absolute-maximum-rated 
conditions for extended periods may affect device reliability.
Power consumption for the PacketMax 5000 base station is a function of the number 
of provisioned MSC cards (backhaul) as well as provisioned WSC (channel elements).
Base Sta-
tion Radio
Antenna
RF Antenna Port
Type-N, Female, 50 
Ohm
IF
IF Port (70 MHz IF Signal and 24 Volt DC Output Voltage)
Type-F, Male, 75 
Ohm
 
Maximum IF Cable 
Length:          
 
 LMR600/Heliax 250 
Meters
 
LMR400 200 Meters
Management
Serial Management Port
 
Not Supported, For Internal Use Only
Mini Sub-D, 9 Pin
Table D-2
Specifications for Interfaces of 4 Sector BS (Continued)
Data Rates
384 kbps to 10 Mbps; Bursts up to 20 Mbps
Frequency Bands
3.3 - 3.6 GHz
Duplexing Mode
Time Division Duplexing (TDD) 
Error Control
Advanced MAC-layer ARQ; Reed Solomon FEC with variable block length and cor-
rection factor.