RadioFrame Networks Inc DH2 Manuale Utente
Method of Procedure
Pre-Installation
Pre-Installation
44
RFN_3.1 Beta
3.5.4 Weight
•
12 lbs (fully loaded with 7 RadioBlades/RAPs)
3.5.5 Power
•
Negative 36-56 Volts DC, 0.8A
3.5.6 Grounding
•
No additional grounding required
3.5.7 Environment
•
Operating Ambient Temperature: 0
o
C to +40
o
C (+32
o
F to +104
o
F)
•
Altitude: -200 to +8000 feet above mean sea level; above 8000', reduce
maximum operating ambient temperature by 2
maximum operating ambient temperature by 2
o
C per 1000' to a maximum of
13000'
•
Storage Temperature: -40
o
C to +70
o
C (-40
o
F to +158
o
F)
•
Relative Humidity: 10-90% non condensing
•
Shock: 40 g’s
•
Vibration: Level 3 earthquake
•
Keep product free from dust, wind, salt, liquids
3.5.8 Heat
Load
•
85 BTUs
3.5.9 RF
Exposure
To comply with FCC RF exposure requirements, iDEN antennas must be
installed to provide at least 9 inches (20 cm) separation from all persons, with
antenna gain not exceeding zero (0) dBi.
installed to provide at least 9 inches (20 cm) separation from all persons, with
antenna gain not exceeding zero (0) dBi.
3.5.10 Cable
Support
•
CAT 5 wiring to ACU