MC-Series System Installation & Testing
Scheduled and Unscheduled Maintenance
94
RadioFrame Networks, Inc.
Index
Part Number
Disconnect From
To
Type
DAT_6
111-0001-02
BIC: CRTC 10base2 - ISC
ISC 1: 10B2-1
COAX
CLK_1
111-0001-02
BIC: ERTM 5MHz/1PPS IN
ISC 1: SITE REF OUT 1
COAX
* Remove both ends of this cable and keep it for the replacement BIC.
For the AIC, disconnect the following cabling from the rear of the AIC only:
Index
Part Number
Disconnect From
To
Type
P_12
820-0614-10
AIC: power
PDU: AIC
power
G_13
820-0609-00
AIC: ground
GND BAR
ground
DAT_1
111-0566-00
AIC: ERTM PORT 1
RBS 1: 10/100 RFN A
UTP
DAT_2
111-0566-00
AIC: ERTM PORT 2
RBS 1: 10/100 RFN B
UTP
DAT_3
111-0566-00
AIC: ERTM PORT 3
RBS 1: 10/100 RFN C
UTP
DAT_5
111-0565-00
AIC: ERTM PORT 4
BIC: ERTM PORT 2
UTP
For the RBS 1, disconnect the following cabling from the rear of the RBS 1 only:
NOTE: If RBS 2 and RBS 3 are present, refer to the cabling diagrams in Appendix C for
corresponding cabling indexes.
corresponding cabling indexes.
Index
Part Number
Disconnect From
To
Type
P_6
820-0616-50
RBS 1: power
PDU: RBS 1
power
G_8
820-0609-00
RBS 1: ground
GND BAR
ground
RF_1
820-0611-20
RBS 1: Tx A
RF Shelf 1: Tx IN A
RF cable
RF_4
820-0611-20
RBS 1: Rx A
RF Shelf 1: Rx OUT A
RF cable
AL_1
820-0607-00
RBS: ALARM INPUT A
RF Shelf 1: ALARM
serial
DAT_1
111-0566-00
RBS 1: 10/100 RFN A
AIC: ERTM PORT 1
UTP
RF_2
820-0611-20
RBS 1: Tx B
RF Shelf 2: Tx IN B
RF cable
RF_5
820-0611-20
RBS 1: Rx B
RF Shelf 2: Rx OUT B
RF cable
AL_2
820-0607-00
RBS: ALARM INPUT B
RF Shelf 2: ALARM
serial
DAT_2
111-0566-00
RBS 1: 10/100 RFN B
AIC: ERTM PORT 2
UTP
RF_3
820-0611-20
RBS 1: Tx C
RF Shelf 3: Tx IN C
RF cable
RF_6
820-0611-20
RBS 1: Rx C
RF Shelf 3: Rx OUT C
RF cable
AL_3
820-0607-00
RBS: ALARM INPUT C
RF Shelf 3: ALARM
serial
DAT_3
111-0566-00
RBS 1: 10/100 RFN C
AIC: ERTM PORT 3
UTP
3
Remove the chassis from the rack, and package it for shipment.
24
Mount the replacement chassis.
While supporting the chassis, slide the chassis into the cabinet mounting position. Secure the
chassis to the cabinet mounting rails using the four mounting screws provided with the unit.
Tighten the screws to 4.5 Nm (40 in-lb).
chassis to the cabinet mounting rails using the four mounting screws provided with the unit.
Tighten the screws to 4.5 Nm (40 in-lb).
35
Reconnect the cabling to the replacement chassis as defined in Step 2.
Use the SMA torque wrench for all SMA connectors.
6
Using the breakers on the PDU, turn up the BIC, AIC, and RBS 1 (and RBS 2 and RBS 3 if
present), and then verify that the components are operational before proceeding.
present), and then verify that the components are operational before proceeding.