8.4.2 GPS surge arrestor
Figure 75 shows the surge arrestor dimensions and Table 31 shows the performance
specifications.
specifications.
Figure 75 PolyPhaser RGT Broadband DC Pass Protector
Table 31 Surge Arrestor Specifications
Current
10 ADC
Insertion Loss
≤ 0.25 dB
Freq. Range
0-2400 MHz
Mounting
Bulkhead
Operating Voltage
+/-60 V
Protected Side Connector
N Female 50 Ω
Replaceable Gas Tube
Yes
Surge Side Connector
N Female 50 Ω
Throughput Energy
≤ 2283 µJ for 3 kA @ 8/20 µs Waveform
Turn-On Voltage
+/-180 Volts
Unit Impedance
50 Ω
Voltage Standing Wave Ratio
1.28 : 1
Weatherized
Bellcore #TA-NWT-000487 Procedure 4.11,
Wind Driven (120 mph) Rain Intrusion.
Wind Driven (120 mph) Rain Intrusion.
8.4.3 RF Feed-Throughs (N-type connectors)
Table 32 Specifications for N-Type Feed-Through Connectors
RFN P/N
Config. / Specs.
S.M Electronics P/N
514-0001-99 Terminator, N-M w/ chain 2 W 6 GHz,
18 dB max VSWR @ 6 GHz
STN0610C