Scheduled and Unscheduled Maintenance
MC-Series High-Power System
998--01
Rev
X1
86
CONFIDENTIAL AND PROPRIETARY
RadioFrame Networks, Inc.
TRADE SECRET INFORMATION
Figure 53 Serial Log Upload Page with IP Address Prompt
3 Copy the contents of the serial log window into a text file and save the text file.
4 Email the text file to the Technical Assistance Center at:
4 Email the text file to the Technical Assistance Center at:
support@radioframenetworks.com
7.8 Power Down Procedure
When powering down the entire MC-Series system, follow these instructions.
Using the breakers on the PDU, power off equipment in the MC-Series system rack in the
following order:
following order:
• BIC
• AIC
• RBS 1 (and RBS 2 if present)
• RF Shelf 1, RF Shelf 2 and RF Shelf 3
• CSU
• Secondary iSC-3; then ensure that the power switch on the front of the unit is in the
• AIC
• RBS 1 (and RBS 2 if present)
• RF Shelf 1, RF Shelf 2 and RF Shelf 3
• CSU
• Secondary iSC-3; then ensure that the power switch on the front of the unit is in the
OFF position
• EAS; then ensure that the power switch on the front of the unit is in the OFF
position