JUMPERS CONFIGURATION
Size ¼ of LR72
Connections with the LR72
P5: “Jumper” for configuration of the
CAN direction of the expansion.
“Jumper” = ON
 “1” logic.
Programmable addresses: 1…63
max
P6: “Jumper” to enable or disable the
Tele-Alignment process.
Enabled Tele-Alignment = “jumper”
placed or ON.
P6
Disabled Tele-Alignment = “jumper”
eliminated or OFF.
P6
1 = VPP (channel power)
2 = GND (Channel ground)
3 = VO (Channel voltaje analogue output)
4 = VR (Zero position voltage, when K rely of
each channel is inactive.