Figure 22: RU Grounding 
 
 
3.5.4 MU CONNECTIONS 
Step1: Connect the MU OP (optical) port to one of the RU OP port. (NOTE: requires Single Mode fiber 
with SC/APC connectors; MAXIMUM OPTICAL LOSS = 6.5dBo) 
 
Step 2: For duplex application, connect the MU RFU TX/RX port to the RF Source (BTS or BDA) using 
50Ohm coaxial cable. For simplex application, connect the MU RFU TX/RX port to the RF Source 
downlink, and then connect MU RFU RX port with RF Source uplink. (NOTE: Coaxial cable must be mini-
DIN Male on the MU side)  
 
Local commissioning & 
Remote monitoring port
BTS Alarm
Reserved
Fiber optic port
RF port, to BTS
LED 
indicator 
 
Figure 23: Fiber Optical and RF Port Connection