Table 6: Commissioning Procedure 
Commissioning Tasks 
Observation 
1.  On-line and Inquiry status 
 
Activate the OMT Main window. The system Initialization will 
completed in about 2 minutes.  
 
Click 
“Connect” button to enquire the repeater’s status. Proceed if 
there is no alarm; else check the failure and attend to the alarm. 
2.  Isolation detection 
 
Detect isolation of service antenna and donor antenna. 
3.  Set Channel No. 
 
 
Keep RF switch ON and set the 
channel number of the repeater’s 
operating frequency. 
4.  Adjust Downlink Output 
Power and align donor 
antenna 
 
Observe DL input power from measured value. Align the direction 
of donor antenna until the DL input power reading is maximized. 
 
Note: To ensure that the measured DL input power is accurate, 
one should set 
the DL ATT to “0” before performing the check. 
5.  Configure [Equipment ID] 
 
Go to [Properties Info] and set [Equipment ID]. 
6.  Comm. Config 
 
Enable the power supply by s
electing “On” in [RF] -> [Switch]; go to 
[Properties Info.] -> [Comm. Config.] and set OMC Phones No. , 
the service No. of SMSC, Report Mode. 
7.  Select Monitoring 
Parameters 
 
Select the equipment controlled and monitored parameters. 
 
If the external devices are connected to the equipment for 
management, please enable in the [External Alarm Info.] Interface. 
8.  Test coverage area field 
intensity and adjust 
service antenna. 
 
 
Use test-handset to verify field intensity within the coverage area. If 
needed, realign the service antenna to achieve the desired 
coverage. 
 
Note: If during operation, the equipment gain could not be set to 
maximmum or the output power is not high enough due to 
insufficient donor and service antennas isolation, then the 
antennas’ position should be changed to increase isolation. If the 
output power is too high and ALC is activated, then adjust the DL 
ATT to achieve optimal DL Gain.  
9.  Verify UL gain and ensure 
test call produces good 
voice quality and there is 
no interfering BTS 
 
Adjust UL gain and perform test calls. Typically, the UL gain is set 
around 5dB less than DL gain. Perform test calls in the coverage 
area while adjusting UL gain if required.  
 
Note: If the repeater is near the BTS and the test call performance 
is poor, this may be due to UL noise interference to the BTS. Users 
can calculate and determine if the repeater UL noise will interfere 
with the BTS. 
 
Verify again that there is no unacceptable interference to BTS. 
 
 
 