Register multiple transmitters to one receiver:  From 1 to 100 
transmitters may be registered with a single receiver.  Simply 
repeat the above steps for each transmitter that you wish to 
register with the same receiver.  Important:  Remember to register 
each transmitter with only one receiver.  Otherwise, when the send 
button is pressed on the transmitter, data will be sent an incorrect 
receiver as well as the correct receiver.   
 
Delete the registration of an individual transmitter to a 
particular receiver:
  Open the small plastic door on the back of 
the transmitter (not the battery door), there you will see a small 
 
Operation 
 
Configure the measurement device:  The measurement device 
may require configuration to allow output of data through the data 
port on the device.  Please refer to the operations manual for the 
measurement device to obtain correct settings. 
 
Connect the wireless receiver to the computer:  Before 
wireless data transmission can occur, the wireless receiver must 
be working properly with the computer that is running Net-Inspect.  
See wireless receiver user instructions for setup procedure. 
 
Test the data transmission from the measurement device into 
Net-Inspect:
  Check to be sure that data is traveling from the 
measurement device through to the computer running Net-Inspect 
software.  First, take a measurement with the measurement 
device.  When the measurement device displays the 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Wireless Data Transmitter 
 
 
User Instructions 
 
 
Introduction 
 
The Net-Inspect wireless data transmitter is designed to transmit 
data from various digital inspection instruments to the Net-Inspect 
Quality System.  The transmitter may be used with many different 
digital inspection devices that have data output capability.  Check 
with Net-Inspect for compatibility and pricing. 
 
 
Setup 
 
Install the battery:  There is a small plastic cover on the back of 
the transmitter that must be slide back to expose the battery 
compartment.  Install a size CR2032 Lithium Coin Cell battery, 
being careful to observe that correct polarity is maintained.  The 
positive (+) side of the battery goes UP.  Slide the plastic cover 
back into place.  To assure the best performance, replace the 
battery every three months. 
 
Connect the measurement device:  The wireless data 
transmitter must be connected to a digital inspection device to 
operate.  There is a short cable on the device with a custom 
connector on the end.  Plug this connector into the inspection 
device. 
 
Register the w ireless transmitter with the wireless receiver:  
In order to operate, each transmitter must be registered with the 
intended receiver.  The transmitter must be registered with only 
one receiver.  To register the transmitter with the receiver, hold the 
transmitter within two feet of the receiver.  Push the "ADD" New 
Transmitter button on the receiver.  The blue status LED (light 
emitting diode) will light on the face of the receiver.  Within 10 
seconds, push the send button on the transmitter.  The blue status 
LED on the receiver will flash 3 times to indicate that the 
transmitter has been correctly registered with that receiver.  With 
each of the 3 flashes, you will also hear a beep from the receiver. 
measurement, press the send button on the Net-Inspect 
transmitter.  The Status LED on the receiver will flash for 1 second 
and a short beep will sound to show that the data has been 
received by the receiver and sent through the serial cable to the 
computer running Net-Inspect.  The data should appear in the Net-
Inspect data entry box on the computer monitor. 
 
If the data does not appear on the Net-Inspect gauge input screen, 
then check the serial connection and configuration.  The setting 
should be 9600, 8, N, 1 with NO Flow Control.  Also assure that 
the serial cable used is a straight through cable without any 
gender changers or null-modems in the line. 
 
If the battery power in the transmitter is too low for proper 
operation:  
When the battery power is too low, the transmitter will 
not transmit.  If you press the send button and know that the 
transmitter is registered with the receiver, then replace the battery 
and retest.  If it still does not work properly, then re-register the 
transmitter with the receiver.  There is no harm in re-registering 
several times if you feel it was not done already.  Test again.  If the 
data does still not appear in the Net-Inspect software, call Net-
Inspect for technical support. 
 
 
 
 
 
 
 
 
push button switch, press and hold the button with the tip of a pen, 
then press the send button on the transmitter.  You must be within 
2 feet of the receiver.  You will hear a long beep (3 seconds) from 
the receiver indicating that the transmitter has been removed from 
the receiver's registration list.  In addition to the 3 second beep, 
the Status led will light for the 3 second period.  That receiver will 
not process future transmissions from that transmitter.   
 
Delete the registration of all transmitters on a particular 
receiver:  
Press and hold the "Delete All Transmitters" button on 
the receiver for 5 seconds.  After you have held the button down 
for 5 seconds, you will hear a 5 second beep and the Status LED 
will flash for 5 seconds.