Installation and Setup
2. Connect the ODU cable to the RJ-45 connector on the IDU panel
designated WAN.
Figure 2-2
illustrates a typical panel of the IDU-E
and IDU-C.
Error! Not a valid link.
Figure
2-2. IDUs connector panels
Other models may have a different configuration for these panels.
Connecting the Power
Before connecting any cable, the protective earth terminals of the
AC/DC power must be connected to the protective ground conductor
of the mains power cord. (Applies to both IDU models.) If you are using
an extension cord (power cable) make sure it is grounded as well.
Any interruption of the protective (grounding) conductor (inside or
outside the instrument) or disconnecting of the protective earth
terminal can make this unit dangerous. Intentional interruption is
prohibited.
AC/DC power must be connected to the protective ground conductor
of the mains power cord. (Applies to both IDU models.) If you are using
an extension cord (power cable) make sure it is grounded as well.
Any interruption of the protective (grounding) conductor (inside or
outside the instrument) or disconnecting of the protective earth
terminal can make this unit dangerous. Intentional interruption is
prohibited.
Power is supplied to WinLink 1000 via an external AC/DC converter,
which receives power from 110–240 VAC source and converts it to
-24VDC or -48 VDC.
which receives power from 110–240 VAC source and converts it to
-24VDC or -48 VDC.
Î
To connect the power IDU-E:
1. Connect the 2-pin plug of the AC/DC converter to the 2-pin DC
power connector on the IDU-E rear panel.
2. Connect the AC/DC converter 3-prong plug to mains outlet.
Î
To connect the power for IDU-C:
•
For AC power model, connect the AC cable 3-prong plug to mains
outlet.
outlet.
•
For DC power model, connect to DC supply on the rack (male
connector for the terminal block is included).
connector for the terminal block is included).
Warning