Chapter 5  Diagnostics and Troubleshooting 
WinLink 1000 Installation and Operation Manual 
Table 5-1.  WinLink 1000 Alarms and Information Messages 
Message Description 
Radio Link – Sync 
Radio link is synchronized 
Radio Link – Out Of Sync 
Radio link lost synchronization 
Link Has Been Reset 
ODU was reset due to internal problem 
TDM Interface – Normal 
TDM interface is operating properly 
TDM Interface – LOS 
Loss of Synchronization is reported by TDM interface 
TDM Interface – LOS 
Loss of Signal is reported by TDM interface 
TDM Interface – AIS 
Alarm Indication Signal is reported by TDM interface 
TDM Interface – Loopback 
A loopback is active on TDM interface 
Link Resetting 
Wireless link reset from the management station. This 
alarm is caused by automatic reset after link 
configuration. 
Local ODU Resetting 
The local ODU reset from the management station. 
Monitor was stopped since no 
connection to the link 
No ODU-to-IDU traffic was detected during the last 20 
minutes. 
5.2  Collecting and Saving Statistics 
WinLink 1000 constantly monitors traffic over the radio link and 
collects the following statistics data: 
• 
Site 1/Site 2 received traffic rate (in Kbps) 
• 
Site 1/Site 2 received frames rate (in Fps) 
• 
Radio signal strength (in dBm) 
• 
Error (Blocks). 
The statistics (monitor) log and event log can be saved as TXT files. 
New alarms are automatically added to the text file, as they enter the 
event log. 
Π
To save event log or monitor log: 
1.  From the Tools menu, choose Preferences. 
The Preferences dialog box appears (see 
). 
2.  From the Preferences dialog box, select the file to save. 
5-2 
Collecting and Saving Statistics