Chapter 5  Diagnostics and Troubleshooting 
WinLink 1000 Installation and Operation Manual 
Q: After reselection Channel Reselection link is not established for long 
time. How can I recover the link? 
A: Click "cancel", then open the site configuration dialog and set the 
unit to install mode. The remote side of the link shall enter install 
mode on the installation channel. 
Services 
Q: What is the actual Ethernet data rate and maximum throughput?  
A: The Max net throughput of the WinLink 1000 is Full Duplex 18 
Mbps.  
 
Note
The WinLink 1000 is a symmetrical system 
 
Q: Does WinLink 1000 withhold any MAC Addresses? 
A: The WinLink 1000 is a layer 2 Bridge (VLAN transparent). The built in 
switch contains a MAC Address table up to 2047. 
Q: What are the BER values expected in the WinLink 1000 link?  
A: 1E-10 (according to BER sensitivity threshold) 
Antennas and Cables 
Q: Can I use any category 5e cable in order to connect the IDU and 
ODU? 
A: The cable should be suitable for outdoor use, and shielded 
Category 5e. 
Competitve 
5-10 
Frequently Asked Questions