ZTE Corporation R8978S2600L Manuale Utente

Pagina di 66
ZXSDR R8978 User Manual
Name
Description
-48 V DC
-48 V DC neutral line
-48 V DC RTN
-48 V DC earth line
PE
Protective grounding cable
5.3 Replacing the AC Power Lighting Protection Box
If the AC power lighting protection box has an abnormal output but the input is normal, it
has some faults and should be replaced immediately.
Prerequisite
l
Verify the hardware type of the faulty AC power lighting protection box. Prepare a
proper AC power lighting protection box. The specifications of the proper AC power
lighting protection box must be consistent with the faulty one.
l
Prepare the following tools.
Tool
Function
Wrench
Installs or uninstalls the outdoor AC power lighting protection
box from a pole
M4 Inner-hexagon wrench
Installs or uninstalls the pole-mounted installation assemblies,
or fastens the anti-theft screws
M6 cross screwdriver
Installs or uninstalls the mounting plate and cables of the
outdoor AC power lighting protection box
Waterproof tape
Provides waterproof protection for the cable connectors
Sticker
Marks the connection of the cables to be replaced (after the
replacement, all the cables must be reconnected to the place
where they were)
Moisture proof antistatic bag
and carton
Stores the faulty AC power lighting protection box
Steps
1.
Power off the ZXSDR R8978.
2.
Remove the waterproof tape from the cables. Uninstall the cables of the AC power
lighting protection box by using the M6 screwdriver
3.
Uninstall the anti-theft screws by using the M4 Inner-hexagon wrench, and uninstall
the mounting plate by using the M6 cross screw driver. Take the AC power lighting
protection box down from the pole.
5-6
SJ-20141113151137-001|2016-08-17 (R1.2)
ZTE Proprietary and Confidential