ZTE Corporation ZXG-BTS2 Manuale Utente

Pagina di 139
 
 
Chapter 4 - System Functions 
Confidential and Proprietary Information of ZTE CORPORATION 87 
Parameter Configuration 
It supports the BTS parameter configuration by the BSC. 
The parameter configuration flow is shown in Figure 69. 
F
I G U R E  
6 9
 
P
A R A M E T E R  
C
O N F I G U R A T I O N  
F
L O W
 
CMM
FUC
CHP
CIP
 
 
The messages from the BSC are sent to the CMM board through the BIE 
board through the LapD link, and then forwarded to application processes 
through the message distribution process of the Abis interface of the CMM 
software. The CMM configuration process processes the configuration 
messages and implements the BTS static data configuration by the BSC. 
The CMM software distributes the BSC parameters, and through the HDLC, 
configures the data to the TRM board FUC software that is managed by the 
CMM software. After receiving the configuration message from the CMM 
software, the FUC software configures the board attributes, notifies the 
CMM software of the successful configuration message at the same time, 
and configures the CHP and CIP. 
Alarm and Status Reporting 
The ZXG10-BTS (V2.9) supports reporting the alarms and status of the 
BTS to the BSC. 
The alarm reporting flow is shown in Figure 70.