64 
Confidential and Proprietary Information of ZTE CORPORATION 
Broadcast Information 1 Change Procedure 
The procedure of broadcast information 1 change is shown in Figure 54. 
F
I G U R E  
5 4
 
B
R O A D C A S T  
I
N F O R M A T I O N  
1   C
H A N G E  
P
R O C E D U R E
 
MS
LAPDm
FURRM
HPIMan
LAPD
BSC
PAGCH
M
DL _ DATA_ IND (BCCH INFO)
(BCCH INFO)
M PH_ 
RRC m dToCHP (CHP 
SET/ STOP BCCH 
INFO)
(CHP SET CCCH 
Para.)
(SYS INFOTYPE
1 /2/ 2bis /2 ter/3/4/ 7/8 )
(PAG SET CCCH Para.)
 
The BSC indicates to the OB06 that the new system messages (like (RR) 
System Information Type 1/2/2bis/2ter 3/4/7/8) will be broadcast on the 
BCCH. 
When the OB06 receives the BCCH INFO message, the FURRM module will 
send the CHP SET BCCH INFORMATION message to the CHP if there is any 
system message. Then, the CHP sends it to the MS. If there is no system 
message, the FURRM module will send the CHP STOP BCCH INFORMATION 
message to the CHP, indicating to stop sending these system messages to 
the MS. 
For easy observation of the system message sending, the TRU panel of the 
OB06 has a signal indicator marked as “MOD”. 
System Information Type 1 contains RACH control parameters and cell 
configuration; System Information Type 2 contains RACH control 
parameters and BCCH configuration of an adjacent cell; System 
Information Type 2bis and System Information Type 2ter are optional 
messages, containing BCCH extension configuration of an adjacent cell; 
System Information Type 3 contains information of other cells, such as 
identifier of a location area and cell identity; System Information Type 4 
contains information of control over RACH, identifier of a location area and 
cell identity; System Information Type 7 and System Information Type 8 
contain parameters of cell reselection. 
The FURRM extracts three parameters (BS_PA_MFRMS, BS_AG_BLKS_RES 
and CCCH_CONF) from the Control Channel Description information unit of 
the System Information Type 3 message, and sends them to the CHP and 
PAGCHM modules.