ZTE Corporation ZXMBW-E9200 Manuale Utente

Pagina di 63
 
ZXMBW E9200 Indoor Pico Base Station User Manual
 
 
 
8      
Confidential and Proprietary Information of ZTE CORPORATION 
 
Index 
Description 
Frequency 
band range 
It supports the band range from 2496MHz 
to 2690MHz. 
Carrier 
bandwidth 
10MHz (configurable) 
RF grid 
250KHz 
RF 
Noise 
coefficient 
< 6 
Duplex 
mode 
FDD/TDD 
It supports TDD.  
Carrier 
sector 
1CS 
MIMO 
It supports 2 x 2 MIMO. 
System 
indexes 
Output 
power of 
antenna 
port 
2×500mW 
Modulation mode 
QPSK,16QAM,64QAM  
Demand for antenna  
omni-directional or directional 
R6 interface 
It supports 10M /100M Ethernet electrical 
interfaces.  
It supports remote upgrading.  
Maintenance  
It supports local OMC and Debug interfaces.  
Environmental 
protection 
It meets the Restriction of Injurious 
Materials in Electric and Electronic Devices 
of European Union ROHS and WEEE 
regulations.  
Air cooling 
Self-cooling and no fan available.  
Followed standards  
IEEE 802.16-2005; WiMAX ForumTM Mobile 
Radio Conformance Tests 
Lightning protection 
It supports level D internal lightning 
protection power.  
Installation mode 
Indoor: wall-mounted and pole-held  
It meets the FCC and UL authentications.  
Authentication 
It meets the CE authentication.  
 
 
GPS clock 
The precision of the system output clock PP1S is not less 
than 1E-10 when the GPS is locked. It is not less than 5E-10 
during free oscillation. 
 
ToP clock 
The ToP over Ethernet clock allows master/slave 
configuration. The duration when the slave clock is locked to 
Clock Index