ZTE Corporation ZXWLW822E Manuale Utente

Pagina di 30
Chapter 5
Installation
Abstract
The ZXWL W822E can be placed on a desk, hung on a wall, or installed to the ceiling.
Pre-requisites
l
The indoor temperature and humidity do not exceed the allowed operation
temperature and humidity.
l
The AP is free from interference within 2-3 meters, for example, cordless phones
and transformers. The AP is free from inflammable and explosive items.
l
The place to install the device is determined. If the place changes, you need to
apply to change the AP design.
l
The distance between the Ethernet switch and the AP is less than 100 meters. At
least 100 mm are left from around the device for heat dissipation.
l
If the AP is installed within a room, the AP must be free from metal blocks within
one meter.
l
If the AP is installed in a weak electricity well, it is 1.5 to 2 meters high from the floor
to ensure ventilation. In addition, the well must be free from dust.
l
If the AP is installed to the ceiling, it must be near the manhole to facilitate
maintenance. If the ceiling is not installed, do not install the AP above the location
where the suspended ceiling will be installed. Otherwise, the AP will be blocked.
Desktop Installation
Place the device on a stable desk. Ensure that it is not easy to be moved and fall on to
the floor.
Wall Installation
To install the ZXWL W822E on a wall, perform the following steps:
1.
Confirm the installation position. Press the adapter to the wall and mark the installation
holes on the wall.
2.
Drill holes based on the marked holes with a percussive drill. The aperture is 6 mm
and the depth is 40 mm. Use a cleaner to clear the dust.
5-1
SJ-20130807102306-001
ZTE Proprietary and Confidential