5.1.3 RF Characteristics
Peak output power: 2 x 0.5W per channel
Average output power: 2 x 100mW per channel (23dBm)
Noise Figure: 5dBm
Transmission Power Control Range: 50dB in 1dB steps
Radio Access Method: OFDM - TDMA
Configuration & Diversity Support: 2X2 MIMO with MRC(RX) and CDD(TX)
Frequency Resolution: 0.25MHz
Channel bandwidth: Configurable 4.2/8.4MHz
FFT Supported: 512
Guard band: 64 sub-carries on each side
Total subcarriers used per symbol: 384
Data carriers used: 336
Pilot carriers used: 48
Sub carrier spacing: 13KHz for 5MHz bandwidth with 5msec frame
Modulations: QPSK
FEC methods: CTC
FEC Ratios: ¾ , ½ , ¼
Error Detection: CRC32
Full TDD asymmetrical duplexing
Flexible ratio from 1:1 to 1:9 in PTP
Resolution of 1% between all units in multi-unit networks.
NOTE – The wide configurable power control range enables transmitting in low
Tx power when not needed, thereby reducing power consumption.
Tx power when not needed, thereby reducing power consumption.