Hewlett Packard Enterprise Company AP134135 Manuale Utente

Pagina di 16
Aruba AP-130 Series Access Point
| Installation Guide
3
Figure 2  AP-130 Series Rear 
Console Port
Use the console port to connect to a terminal for direct local management.
Ethernet Ports
AP-130 Series is equipped with two10/100/1000Base-T (RJ-45) auto-sensing, MDI/MDX wired-network 
connectivity port. These ports support IEEE 802.3at Power over Ethernet (PoE) compliance, accepting 
56VDC as a standard defined Powered Device (PD) from a Power Sourcing Equipment (PSE) such as a PoE 
midspan injector, or network infrastructure that supports PoE.
DC Power Socket
If PoE is not available, an optional Aruba AP AC-DC adapter kit (sold separately) can be used to power the 
AP-130 Series. 
Reset Button
The reset button can be used to return the AP to factory default settings. To reset the AP:
1. Power off the AP.
2. Press and hold the reset button using a small, narrow object, such as a paperclip.
3. Power-on the AP without releasing the reset button. The power LED will flash within 5 seconds.
4. Release the reset button.
The power LED will flash again within 15 seconds indicating that the reset is completed. The AP will now 
continue to boot with the factory default settings.
AP-134_002
CONSOLE
ENET 1
ENET 0
Reset Button
DC Power Socket
Kensington Security Slot