Hideki Electronics Limited TS906 Manuale Utente

Pagina di 5
Instruction Manual of TS906(Draft Copy) 
 
Remote Rain Gauge: 
 
 
Setting up the Rain Gauge 
1.
  Unlock the funnel-shaped top of the rain sensor by turning both knobs on the sides of the rain 
sensor in an anti-clockwise direction. 
2.
  Lift the top off the base and insert two 2 x UM-3 or “AA” size 1.5V batteries into the battery 
holder. 
3.
  Replace the lid and secure into place by turning the knobs clockwise. 
4.
  Place the rain sensor in a location such that precipitation can fall directly into the sensor, ideally 
2-3 ft above the ground. 
It may be secured into place by using the four screws provided. 
5.
  The sensor must be accurately level for optimum performance. To check if the sensor is level, 
remove the lid and check if the ball bearing inside is at the midpoint of the leveler.
 
Additionally, a 
bubble level or carpenter’s level may be used. 
6.
  Attach the protective screen onto the top of the lid. The screen will prevent any debris entering the 
sensor. 
 
Placement tips: 
-
  The rain sensor should be placed in an open area away from walls, fences, trees and other 
coverings which may either reduce the amount of rainfall into the sensor, deflect the entry of 
wind-blown rain, or create extra precipitation runoff. Trees and rooftops may also be sources of 
pollen and debris. 
-
  To avoid rain shadow effects, place the sensor at a horizontal distance corresponding to two to four 
times the height of any nearby obstruction.