Controlled Electronic Management Systems Ltd INFOPROX Manuale Utente

Pagina di 79
InfoProx Hardware Installation 
 
InfoProx Entry   
·  Input 2 is for request to exit (NO) 
·  Input 3 is spare. (NC) 
The InfoProx Entry door control unit has a single-pole relay with a set of dry 
contacts rated at 5 amps at 30 volts DC maximum. The common and normally 
opened connections are available on pins 9/10 of J2.  For normal door mode, this 
relay is reserved for door strike control (the relay operates when a valid card is 
presented). The four inputs and the relay output are located in a 10-pin Phoenix 
contact connector J2, as shown below. The relay can be configured as “Powered 
to Unlock” or “Powered to Secure”. 
C
NO
J2
Relay
Contacts
1
Input 3
(spare)
Input 2
Input 1
Input 0
2
3
4
5
6
7
8
9
10
 
Figure 5: Inputs and Outputs on J2 
The power supply must have sufficient capacity to operate the door strike, as 
indicated in Table 1. Three optional switches can be connected. 
·  The door state monitor is a normally closed switch (Input 0) whose 
contacts are closed when the door is closed. The switch must be used 
for the InfoProx Entry to generate the door held and door open alarms. 
·  The lock status switch (Input 1), if present, is usually part of the door 
strike assembly, and must be connected if lock status monitoring is 
enabled. This is a normally closed switch. 
·  The normally open exit pushbutton switch (Input 2) is used if the door 
lock must be released to leave the secured area. 
18  