1.6 UL 
Information 
1. 
The suitability of the supplied Ethernet cable is subject to the approval of Authority 
Having Jurisdiction and must comply with the local electrical code. 
2. 
The equipment must be properly grounded according with NEC and other local 
safety code and building code requirements 
3. 
To meet the over-voltage safety requirements on the telecommunications cables, a 
minimum 26 AWG telecommunication line cord must be used. 
4. 
"Pour être en conformance avec les exigences finies de sûreté de sur-tension sur les 
câbles de télécommunications un fil de télécommunication ayant un calibre minimum 
de 26 AWG doit être utilisé." 
5. 
Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC 
which provides guidelines for proper grounding and, in particular, specifies that the 
cable ground shall be connected to the grounding system of the building, as close to 
the point of cable entry as is practical.
 
6. 
AN-80i must be installed in compliance with relevant articles in National Electrical 
Code-NEC (and equivalent Canadian Code-CEC) including referenced articles 725, 
800 and 810 in NEC. 
7. 
RF coaxial cable connecting an antenna to AN-80i must comply with the local 
electrical code. 