Agrident Corporation ASR500 Manuale Utente

Pagina di 59
05.07.2007 
 
Page 57 of 59 
 
 
 
ASR500 Reader Operation
 
14.3  Description of the registers 
Register 
Cfg_ 
Adr 
Bits to 
Set 
Hex value 
of 
Settings 
Significance of the registers or their configuration 
Cfg_ 
Delaytime 
0x35   
0x01* 
Time interval for repeated ID message 
Repetition blockage for time 't' of an already transmit-
ted/saved ID message: 
Time 't' = register value * approx. 50 ms (0x00 results in 
no repetition) 
 
0x01* 
Format of the ID message 
0 0x01 ASCII 
notation 
0x02 
Transponder byte structure 
0,1 0x03  Compact 
coding 
1,2 0x06  Output 
of 
raw data without CRC 
0,1,2 
0x07 
ASCII short format 
Cfg_ 
Format 
0x32 
5** 
0x20 
Use SCP format 
 0x00* 
Operation 
mode 
 
0x01 
Slave continuous mode 
 
0x02 
Slave request mode 
Cfg_Mode 0x31 
 0x00 
Master 
mode 
Cfg_Node 0x36  
0x01* 
Individual 
network 
address of a reader; Range of values: 
0x00 to 0xEF, except 0x02,0x03,0x10 
 
0x0E* 
Configuration of the RF interface 
0x02 
FDX-B reception activated 
0x04 
HDX reception activated 
 
0x06 
FDX-B and HDX activated 
0x08 
H4002 reception activated 
 
0x0A 
FDX-B and H4002 activated 
 
0x0C 
HDX and H4002 activated 
 
0x0E 
FDX-B, HDX and H4002 activated 
Cfg_RF 0x33 
0bxx1x100x Use 125 kHz (this option is possible if only H4002 trans-
ponders activated) available at version 1.61 or later 
Cfg_ 
Time-out 
0x34   
0x01* 
Time in which the field is active 
After the time-out period the field activated with 
Get_single_ID is switched off unless a transponder is 
detected within the time interval (after this the field is 
switched off immediately); 
Time = register value x approx. 100 ms 
(Value 0x00 also yields approx. 100 ms)  
 
* Default values specified. 