INCLUDING  ZRW103 TO THE NETWORK
STEP 1..   Prepare the Controller to include a unit to the network by adding it to a group (method of adding a node
to the network).  Refer to controller instructions.
STEP 2.    The ZRW103 must be in its permanently installed location.  Tap either the top or bottom of the
ZRW103 once.
STEP 3.    You should see an indication on your Controller that the “DEVICE WAS INCLUDED” in the network.
NOTE:  If you have trouble adding the ZRW103 to a group it may be that the Home ID and Node ID were not
cleared from it after testing.  You must first “RESET UNIT” with your controller to remove it from the network.  If
using the ZTH100, select “SETUP” and scroll to “RESET UNIT”
Although adding it to a group includes it in the network, removing it from a group does not remove it from the
network.  If removed from a group, it functions as a repeater (only).   “RESET UNIT”  removes it completely from
the network.
BASIC OPERATION
 (Local Control)
The switch paddle on the ZRW103 allows the user to:
•  Turn the attached load on or off.
•  Include or exclude the module from the Z-Wave system
•  Control other Z-Wave enabled devices.
Also, when a controller prompts you to “Send Node ID” or to “Press Button on Unit”, quickly tap the switch on or
off once to satisfy those instructions.
•  Tapping top of switch turns the load attached ON.
•  Tapping bottom of switch turns the load attached OFF.
•  Pressing and holding switch does not effect the load attached to the ZRW103, but will allow dimming and
brightening of Z-Wave dimmers if associated (see below for details).
LED indication
The LED on the ZRW103 will turn on when the load attached is ON. The LED can be user configured however to turn
ON when the load attached is OFF, if so desired, to act as a night light. See ADVANCED OPERATION section.
The ZRW103 will flicker its LED when it is transmitting to any of its 2 groups.  This can be changed if desired.  See
ADVANCED OPERATION section.
Auxiliary Switch
The ZRW103 supports the AS101 auxiliary switch to provide 3-way or 4-way operation.
Remote Control
The ZRW103 will respond to BASIC and BINARY commands that are part of the Z-Wave system. Refer to your
controller’s instructions as to whether your controller can transmit those commands.
Internal circuit protection
The ZRW103 internal circuitry is protected by an internal fuse.  This internal fuse is factory serviceable only.  Check
your home circuit breakers before concluding that the product must be returned to manufacturer for repair at a nominal
charge.
ADVANCED OPERATION
All On/All Off
The ZRW103 supports the ALL ON/ ALL OFF commands.
The ZRW103 can be set to respond to ALL ON and ALL OFF commands four different ways.
Refer to your controller for information on how to set the ZRW103 to operate in the manner you desire. Some
controllers may be only able to set certain settings of ALL ON/ALL OFF response.
The four different ways the ZRW103 can be setup to respond to ALL ON and ALL OFF commands are: