 EHS8 Hardware Interface Overview 
Page 24 of 43
 
 
EHS8_HIO_v02.770 
2014-08-11
 
Confidential / Preliminary
 
potential interferers may be minimized by placing small capacitors (47pF) at suspected lines 
(e.g. RXD0, RXT0, VDDLP, and ON).  
While developing SMT applications it is strongly recommended to provide test points 
for certain signals, i.e., lines to and from the module - for debug and/or test purposes. 
The SMT application should allow for an easy access to these signals. For details on 
how to implement test points see 
[3]
. 
The EMC measures are best practice recommendations. In fact, an adequate EMC strategy 
for an individual application is very much determined by the overall layout and, especially, the 
position of components. For example, mounting the internal acoustic transducers directly on 
the PCB eliminates the need to use the ferrite beads shown in the sample schematic.  
Note: EHS8 is not intended for use with cables longer than 3m. 
Disclaimer 
No warranty, either stated or implied, is provided on the sample schematic diagram shown in 
Figure  6
  and  the  information  detailed  in  this  section. As  functionality  and  compliance  with 
national  regulations  depend  to  a  great  amount  on  the  used  electronic components  and  the 
individual  application  layout  manufacturers  are  required  to  ensure  adequate  design  and 
operating safeguards for their products using EHS8 modules. 
2.4 Sample Application