Tranzeo Wireless Technologies Inc GNVPZ1NT3 Manuale Utente

Pagina di 156
Chapter 20:Firmware Management 
 TR0153 Rev. E1 
 
153 
7.  Click  on  “Install  All”.  Text  indicating  that  the  node  is  being  upgraded  will  be  displayed 
next to the device IP address under the “Nodes Associated with this Gateway” heading. 
8.  Wait for the upgrade to complete (approximately 20 minutes). 
20.2.2 
Upgrading the Firmware on an Individual Device 
The  firmware  can  be  upgraded  on  an individual device  using  the  “Upgrade  Node”  tab  on the 
“Upgrade” page. This is the only tab that is available on devices configured as repeaters. This 
page displays the following information: 
 
•  Firmware currently installed on the EnRoute500 
•  Firmware available on the remote upgrade server 
•  Firmware available in the non-volatile memory of the EnRoute500 
•  Space used/available in non-volatile memory for storing upgrade images 
 
Caution  should  be  used  when  updating  the  firmware  on  a  single  device  in  a 
mesh  neighborhood.  It  is  advisable  to  upgrade  the  devices  that  are  the  most 
hops  away  from  a  gateway  first  and  keep  upgrading  devices  that  are 
successively closer to the gateway, upgrading the gateway firmware last. 
 
Follow the procedure below to upgrade the firmware on a device: 
 
1.  Select the firmware version you want to upgrade to from the “Firmware on Server” box  
2.  Click on the button with the arrow to the right of the “Firmware on Server” box. This will 
begin  the  download  process  of  the  firmware  from  the  Tranzeo  upgrade  server  to  the 
non-volatile  memory  on  the  EnRoute500. While  the  firmware  is  downloading, it  will  be 
shown in blue in the “Firmware on Gateway Node” box.  
 
If  the  completion  percentage  does  not  update,  click  on  the  “Upgrade  Node”  tab  to 
update it. 
 
3.  When  the  download  has  been  completed,  select  the  firmware  you  wish  to  upgrade  to 
from the “Firmware on Node” box. 
4.  Click on the “Install” button. 
5.  Wait  for  the  install  to  complete.  The  EnRoute500  will  reboot  automatically  when  the 
upgrade has been completed.