Initial Configuration of an EnRoute500 
This user’s guide provides a comprehensive overview of all of the EnRoute500’s features and 
configurable  parameters.  However,  it  is  possible  to  deploy  a  network  of  EnRoute500s  while 
only changing a limited number of parameters. The list below will guide you through a minimal 
configuration procedure that prepares a network of EnRoute500s for deployment.  
 
Change the ‘admin’ password.  
The  default  password  should  be  changed  to  prevent 
unauthorized access to the EnRoute500. 
See section 8.1 
Set the operating scheme for the EnRoute500 
Most EnRoute500s will be configured as repeaters, with at least 
one  EnRoute500  per  mesh  neighborhood  configured  as  a 
gateway. 
See section 8.2 
Set the node and mesh IDs 
The node and mesh IDs uniquely identify an EnRoute500. 
See section 8.3 
Set the DNS servers 
Specify DNS servers to allow hostnames to be resolved. 
See section 8.6 
Set the mesh radio channel 
The mesh radios on all EnRoute500s in a mesh neighborhood 
must be set to operate on the same channel. 
See section 10.1 
Set the mesh ESSID 
Set  the  mesh  interface  ESSID  to  a  common  value  for  all 
EnRoute500s  in  a  mesh  neighborhood.  It  should  be  different 
than the ESSID for any adjacent mesh neighborhoods. 
See section 10.2 
Set the AES encryption key for the mesh 
Change the default AES encryption key to prevent unauthorized 
access  to  the  mesh.  The  mesh  encryption  key  must  be  the 
same for all EnRoute500s in a mesh neighborhood. 
See section 10.3 
Set the mesh radio transmit power 
Set the mesh power to the maximum allowed value to achieve 
the best possible connectivity in the mesh. 
See section 10.4 
 
In  addition  to  setting  the  parameters  on  the  “Minimal  Configuration”  page, 
OnRamp  access  should  be  disabled  after  initial  programming.  See  section 
8.16 for instructions on how to enable OnRamp access to the EnRoute500.