Secure Care Products Inc INDOORNODE2 Manuale Utente

Pagina di 46
Doc. No.:  A03490690   Rev.: 1   ECO: 12274   Date     11/10/2016    22 
SECTION 8    THEORY OF OPERATION 
Real Time Location System 
There are several types of Real Time Location System (RTLS) technologies.  The ENVisionIT system can 
determine a tag location by the data each node sends to the system.   
 
The Secure Care ENVisionIT RTLS system uses a minimum of 4 node transceivers to locate a tag.  The receivers 
communicate with a primary node for synchronization and management.   
 
Each node is located in a very precise location within the monitored area.  Using this information along with the 
time difference the signal arrived at each node (TDOA), the ENVisionIT system plots the tag location. 
 
The nodes can use WiFi or LAN for communications between nodes and the ENVisionIT server. 
Ultra-Wideband 
Ultra-wideband (UWB) is a radio technology that uses a very low energy level for short-range, high-bandwidth 
communications over a large portion of the radio spectrum.  This system operates in the 4GHz and 6GHz spectrum. 
Depending on the country, the ENVisionIt system will either be configured for UWB band 2 or UWB band 5.  Most 
installations in the U.S. will use UWB band 5.  UWB band 2 is used in Canada, Australia, and New Zealand and 
other countries in Europe. 
ENVisionIT RTLS Nodes 
The ENVisionIT nodes are microprocessor-based units that recognizes UWB signals sent from Secure Care 
Products RTLS Tags.  Communication between nodes is via Wi-Fi or wired network switch and the Windows server 
running Secure Care ENVisionIT software. 
 
The nodes are categorized into either an ANCHOR node or a standard node.  
Every node must either be an anchor node or have at least one anchor node associated with it. 
 
The standard node communicates with the anchor node for synchronization and control. Each node will send the tag 
information it is detecting along with the position information to the server. 
 
The anchor nodes then passes that information on to the ENVisionIT system.  Once the ENVisionIT system has 
received the information from the nodes, it can calculate the tag position and report it on the GUI. 
 
Communications between the nodes and RTLS tags is over UWB communications. Tag recognition is via MAC 
address, the last 4 octets of which are decoded as the TAG ID. 
 
Anchor nodes use MAC addresses to talk to standard nodes.  All nodes use their assigned IP address to 
communicate to the ENVisionIT system. 
Anchor NODE 
Anchor to Standard node communication 
The master node is responsible for the synchronizing of the nodes it is master for with the rest of the ENVisionIT 
system.  This synchronizing of nodes is critical to correct operation of the system. 
 
It also manages the data from each node, and relaying that data on to the ENVisionIT system. 
 
The nodes will auto-establish a network with other nodes upon power up.  They will continually look for other 
nodes and will begin receiving data from them once they are configured into the ENVisionIT systems Device 
Configuration.