80
Commissioning
Chapter 3 - Commissioning
3.2
Operation Verification
The following sections describe how to verify the correct functioning of the 
Outdoor Units, Indoor Units, Ethernet connection and data connectivity.
3.2.1
AU-ODU LEDs
To verify the correct operation of the AU-ODU, examine the LED indicators located 
on the bottom panel of the outdoor unit. 
The following tables list the provided LEDs and their associated indications.
3.2.2
Base Station LEDs
To verify the correct operation of the Base Station equipment, examine the LED 
indicators located on the front panels of the modules. The following tables list the 
LEDs of the Base Station modules and their associated indications.
NOTE
Verifying the correct operation of the Outdoor Unit using the LEDs, as described below, is only 
possible after the configuration of basic parameters has been completed.
Table 3-2: AU-ODU-LEDs
Name
Description
Functionality
PWR Power 
indication
„
Off - Power failure
„
Green - Power to ODU is OK, internal 3.3 
VDC power supply is OK.
ALARM
IDU-ODU communication 
and synthesizer status 
indication
„
Off - IDU-ODU communication is OK, 
synthesizer is locked.
„
Red - IDU-ODU communication failure or 
synthesizer is not locked
ETH
Not Used