Operation Verification
BreezeMAX Modular Base Station System Manual
85
3.2.5
Verifying the Ethernet Connection
After connecting the unit to an Ethernet outlet, verify that the Ethernet Integrity 
Indicator, which is the yellow LED embedded in the DATA port connector, is on. 
This indicates that the unit is connected to an Ethernet segment. The Ethernet 
Activity Indicator, which is the green embedded LED, should blink whenever the 
unit receives or transmits traffic on the DATA port.
Active GPS - INT
INT GPS selection indication
„
Green - indicates that the selected GPS Receiver: 
is INT (Internal). Internal is not supported in current 
release.
„
Off - INT GPS Receiver is not selected
INT CLOCK
Internal clock source indication
„
Green - Internal 16MHz clock is ok (not supported 
in current release)
„
Red - Internal clock is not available or clock failure
Table 3-9: GPS Adapter LEDs