The default is -73 dBm.
4.5.2.5
Cell
The Cell parameters provide a unique identifier for the Base Station, and they are 
common to all AUs in the Base Station. Updated Cell parameters are applied for 
each AU after resetting the AU (or after resetting the NPU, which causes reset of 
all AUs). The Cell menu enables viewing/updating the following parameters:
4.5.2.5.1
Operator ID
A unique identifier of the network. The same Operator ID must be defined for all 
Base Stations in the network, and it should not be used by any Base Station 
belonging to another network in the same area.
The Operator ID consists of 3 groups of up to three digits each, where the range 
for each group is 0 to 255.
The default Operator ID is 186.190.0.
Changes in the value configured for the Operator ID are applied only after reset.
4.5.2.5.2
Cell ID
A unique identifier of Base Station. The same Cell ID should not be used by any 
other Base Station belonging to the network.
The Cell ID consists of 2 groups of up to three digits each, where the range for 
each group is 0 to 255.
The default Cell ID is 0.250.
Changes in the value configured for the Cell ID are applied only after reset.
4.5.2.6
Duplex
The Duplex parameters define the operation mode of the system. These 
parameters are applied after reset. The Duplex menu enables viewing/updating 
the following parameters:
4.5.2.6.1
Duplex Mode
The operation mode of the system: TDD or FDD.
NOTE
The actual range that can be accepted by AUs operating in TDD mode is -80 to -74 dBm. If a value 
higher than -74 dBm is configured at the Base Station level, the actual value in the AUs will be -74 
dBm (hence the actual default at the AUs is -74 dBm). If a value lower than -80 dBm is configured at 
the Base Station level, the actual value in the AUs will be -80 dBm. You can see the actual value of 
the Optimal Uplink RSSI in the Show menu of each AU (if the configured value differs from the 