Base Station Menu
BreezeMAX Modular Base Station System Manual
107
4.5.2.7.1.2
External 16 MHz Clock
The 16 MHz clock source is used for generation of all main clocking signals in the 
system, including the internal 1PPS clock. Using an external, accurate 16 MHz 
clock source will enable better hold-over of the 1PPS clock upon temporary loss 
(or reduced reliability when receiving less than 4 satellites) of the external 1PPS 
clock. This will allow a longer time of continued operation before appearance of 
interferences due to clock drifts among Base Stations.
The available options are Enable (use external 16 MHz clock source) and Disable 
(use internal 16 MHz clock source).
The default is Disable 
In the current release, external 16 MHz clock from the GPS Adapter is not 
available.
4.5.2.7.2
Chain
Future versions of BreezeMAX will enable chaining of co-located Base Stations to 
fully support intra-site synchronization. When two or more Base Stations are 
chained, all clocks and additional parameters required to ensure fully 
synchronized operation of all sectors are sent from the Master Base Station to 
other Base Stations. The Chain menu includes parameters that must be shared 
by all Base Stations belonging to the same chain, where most of them should be 
configured only in the Master Base Station (they will be read-only in other chained 
Base Stations).
In the current release chaining is not supported yet and all Base Stations are 
configured as Master Base Stations.
The Chain menu includes the following:
4.5.2.7.2.1
Chain Number
In future releases, when chaining will be fully supported, the Chain Number will 
be used as a unique identifier of a chain. All Base Stations belonging to the same 
chain should be configured with the same Chain Number. The Chain Number can 
be used by a central management system to guarantee that certain limitations are 
met: in each chain, one, and only one Base Station should be defined as Master. 
Only one Base Station can be defined as Redundant (backup to the Master).
The range is from 1 to 1500.
The default is 0, indicating that a Chain Number is not configured yet. A valid 
Chain Number must be configured, and this number must be unique in the 
system to properly support future implementation of chaining.