Alvarion Technologies Ltd. BMAX-BA36 Manuale Utente

Pagina di 334
SU Menu
BreezeMAX Modular Base Station System Manual
191
of the relevant antennas. At the end of the scanning period, the SU reaches a Best 
BST/AU decision according to the information gathered. The AU with the highest 
quality mark is selected as the Best BST/AU, and the SU will immediately try to 
associate with it using the relevant frequency and antenna.
The range used for scanning is defined by the BST/AU ID and BST/AU ID Mask 
parameters of the SU. The initial range can be limited by defining a preferred 
range of BST/AU IDs, and selecting the best AU in the preferred range. If no AU is 
found in the preferred range, the SU will scan the entire range.
The Best BST/AU Parameters menu includes the following options:
4.10.7.3.10.1Show
The Show option enables viewing the following:
„
Best BST/AU Support
„
Preferred BST/AU ID
„
Preferred BST/AU ID Mask
„
Selected BST/AU ID 
„
Selected Downlink (Rx) Frequency
„
Preferred BST/AU ID
„
Preferred BST/AU ID Mask
„
Best BST/AU Table, displaying for each AU with which the SU can 
communicate (including the selected AU) the following parameters:
‘
BST/AU ID
‘
Downlink (Rx) Frequency (MHz)
‘
SNR (dB)
‘
Rx Antenna
4.10.7.3.10.2Update
The Update option enables configuration of the following parameters (changes in 
Best BST/AU parameters take effect only after reset):