Alvarion Technologies Ltd. BMAX-BA36 Manuale Utente

Pagina di 334
Completing the Software Upgrade (Switching Versions)
BreezeMAX Modular Base Station System Manual
263
A.3
Completing the Software Upgrade 
(Switching Versions)
After verifying successful upload of all software files, set the new version as the 
main version in each one of the upgraded system elements:
„
SU(s): Select the SU that should be upgraded. Select Unit Control > SW 
Versions Control > Set as Main
, and enter the new SU SW Version. The unit will 
reset automatically and will use the new version after power-up. Repeat the 
process for all SUs that should be upgraded.
„
AU(s): Select the AU that should be upgraded. Select Unit Control > SW 
Versions Control > Set as Main
, and enter the new AU SW Version. The unit will 
reset automatically. After power-up, the unit will use the new version. Repeat 
the process for all AUs that should be upgraded.
„
NPU: Select Unit Control > SW Versions Control > Run from Shadow. The system 
will reset automatically. After power-up, the NPU will run from the new 
version, that at this stage is still marked as the Shadow Version. To switch 
versions, select Unit Control > SW Versions Control > Set as Main.