Installation
Chapter 2 - Installation Guidelines
2.3.2.1
Preparing a Power Cable
A 2.5m DC power cable is supplied with each ODU Power Feeder module. 
Additional DC cables can be ordered from Alvarion. If necessary, use the following 
instruction to prepare a DC cable.
1
Use a cable capable of supporting a current of at least 10A. Use a cable with 2 
x 10AWG (or thicker) wires for the power plus an additional 10AWG to 20AWG 
ground wire.
2
The matching power connector to be used is Amphenol D-type power P/N 
177TWA/3W3/SP3Y with high power socket contacts P/N 17DM53744-1.
3
Connect the cable to the power connector as follows:
‘
Pin 1 (RTN): Red (10 AWG min wire)
‘
Pin 2 (-48V): Black (10 AWG min wire)
‘
Pin 3 (
): Ground (shield) (10AWG-20AWG wire)
4
Attach suitable terminal rings to the side that connects to the power source.
2.3.3
Installing the ODU Power Feeder
The ODU Power Feeder should be installed as close as possible to the location 
where the IF cable(s) enters the building. The location of the ODU Power Feeder 
should take into account its connection to the power source and to the Base 
Station equipment.
Table 2-14: ODU Power Feeder LEDs
Name 
Description
Functionality
PWR
Input power indication
„
Off - ODU Power Feeder is not powered
„
Green - ODU Power Feeder power is OK
ODU PWR 1 - 4 
Output power indications
„
Off - AU-ODU-HP is not connected
„
Red - Power output problem (short or overload)
„
Green - AU-ODU-HP is connected and powered
To prepare the power cable: