E Series Data Radio – User Manual
 © Copyright 2005 Trio DataCom Pty. Ltd.
Part E –  Getting Started - EB450
Digital Inputs and Outputs
The EB450 provides a facility for two channels of digital user inputs 
and outputs (Digital User I/O). Information on how to control and 
monitor this I/O using TVIEW+ Diagnostics can be found in Part J 
- TVIEW+ Management Suite -  Remote Diagnostics & Network  
Controller.
All user I/O is optocoupled for isolation between the EB450 and 
uses equipment. When using the I/O facility the I/O electrical 
characteristics and ratings must be observed. Failure to observe 
these ratings may result in equipment damage.
Inputs
Two User Inputs are available. They have identical interface 
characteristics. Each input has an internal resistance of 470 Ohms. 
Some form of switching contact (ie: switch, relay) is normally used 
to change the state of the input. Both an isolated and non-isolated 
input configuration is possible.
Typical Radio Setup
Is
TVIEW+ Diagnostics will recognise an input as being ON when the 
switch is closed. If the switch is open (or not connected) TVIEW+ 
diagnostics will recognise the inputs as being OFF.
Outputs
Two User Outputs (Open Collector) are available. They have 
identical interface characteristics. The maximum current allowed 
through each output is 20ma. External resistors must be used keep 
the current below this value.
Each output has an internal resistance of 100 Ohms.Ohms law can 
be used to calculate the resistance required for a specific voltage 
(keeping the current below 20mA). Nominally 1k Ohm is used for a 
+13v8 supply and 330 Ohms for a +5v supply.
When the OUTPUT is OFF, V = Vs. No current will flow when 
output is off.
When the OUTPUT is ON, V = nominally 2.3 volts . Current is set 
by resistor.