4. LED indication: 
 
The POWER LED indicates that the power is fed from external power supply.
 
The CM LED indicates that the RF channel is busy when a signal above -107dBm is detected.
 
The PTT LED is turn on whenever the radio transmits (RF).
 
The DATA LED indicates when data is exchanged between the PC and the RFM200.
 
The PROG LED indicated that prameters are trsnmitted between the PC and the RFM200.
 
 
 
 
5. Radio RF calibration: 
 
The radio power and radio deviation are fixed and can’t be changed. The frequency is based on 
TCXO 32.000MHz that has maximum 1ppm temperature stability. The procedure of frequency 
calibration is by try and error loop i.e. measuring the RFM200 carrier transition frequency error, 
setting the freq offset and measure the frequency again until the frequency error is less than 
0.5ppm. 
6. Parameter Setting by GUP: 
The frequency is set by the GUP PC application through the front panel micro USB connector.