Honeywell International Inc. 1981A Manuale Utente
12 - 6
*Storage outside of this temperature range could be detrimental to battery life.
CCB01-010BT Charge Base Product Specifications
CCB02-100BT Industrial Charge Base Product Specifications
Mechanical Drop
Operational after 50 drops from 6.5 feet
(1.98m) to concrete at 23°, -30°, and 50°C
(1.98m) to concrete at 23°, -30°, and 50°C
Vibration
Complies with MIL-STD-810G, Method 514.6, Annex C
ESD Sensitivity
Up to 20kV direct air
Up to 8 kV indirect coupling plane
Up to 8 kV indirect coupling plane
Sealant Rating
IP65
Parameter
Specification
Dimensions (Typical):
Height
3.2 inches (8.13cm)
Length
5.19 inches (13.18cm)
Width
3.98 inches (10.11cm)
Weight
6.3 oz (179g)
Voltage:
4.5 to 5.5 volts
Current Draw:
Host Terminal Port
500mA
Aux Power Port
1A
Charge Time
5 hours
Radio:
Frequency
2.4 to 2.5 GHz (ISM Band) Frequency Hopping Bluetooth v.2.1
Range
33 ft. (10 m) typical
Data Rate
Up to 1 MBps
Temperature Ranges:
Operating
32
° F to +122° F (0° C to +50° C)
Battery Charge
41
° F to +104° F (5° C to +40° C)
Storage
-40
° F to +158° F (-40° C to +70° C)
Humidity
Up to 95% non-condensing
Mechanical Drop
Operational after 50 drops from 3.28 feet
(1 m) to concrete
(1 m) to concrete
Vibration
5G Peak from 22Hz to 300Hz
ESD Sensitivity
Up to 15kV direct air
Up to 8 kV indirect coupling plane
Up to 8 kV indirect coupling plane
Parameter
Specification
Dimensions (Typical):
Height
2.6 in. (6.6cm)
Length
9.8 in. (24.98mm)
Width
4.05 in. (10.28cm)
Weight
10.05 oz. (285g)
Voltage:
4.5 to 5.5 volts
Current Draw:
Host Terminal Port
500mA
Aux Power Port
1A
(Continued)Parameter
Specification
Preliminary draft_1