Bottom Panel
For details on how to mount the Net Base, see 
Power
The terminal requires 12 Volts DC input for communications and battery charging; the power adapter on 
the power cable converts the voltage from the power source to 12 volts DC. Use only UL Listed power 
supply, which has been qualified by Honeywell with output rated at 12VDC and 8.5 amps with the device. 
The operating temperature range is -10° to 50°C (14° to 122°F).
Honeywell recommends that you leave the Net Base connected to its power source at all times, so that it 
is always ready to use. 
We recommend use of Honeywell peripherals, power cables, and power adapters. Use of any non-Honeywell 
peripherals, cables, or power adapters may cause damage not covered by the warranty.
Connecting Power to the Net Base
1.
Plug the A/C power cord into the power adapter.
2.
Plug the power connector cable into the power connector on the back of the Net Base.
3.
Plug the A/C power cord into a standard wall outlet. The LED on the Power Adapter illuminates to 
indicate power.
4.
All four Power/Dock LEDs illuminate solid red to indicate the base has power. Terminal wells with 
properly docked Dolphins indicate power with a green LED.
5.
The base is ready to begin charging terminals.
Compliance Label
Serial Number Label
MAC Address Label
!
Power Connector Cable
A/C Power Cord
Power 
Adapter
LED