Part Replacement Procedures 
6-33 
DIAD 6 Charge Rack Manual 
 
 
 
 
6-Slot Terminal Bay - 50143872-001FRE 
 
 
6-Slot Terminal Bay - 50143872-001FRE 
 
 
Part Name: 
 
6-Slot Terminal 
 
 
 
 
Part #: 
 
 
50143872-001FRE 
 
Tools Required: 
 
1 medium #2 Phillips head screw driver 
 
 
 
 
   
Before working on the Charge Rack, always disconnect the AC cord from the power 
supply. 
   
After removing power, wait 15 minutes before servicing the unit to avoid shock. 
Isolate screws by size as you remove them to ensure proper placement when reinstalling. 
 
1.  Remove the 6-slot bay from the Charge Rack. 
2.  Disconnect the 6 cables between the I/O and power boards. 
3.  Remove all of the screws and then remove all of the boards. 
4.  Replace the 6-slot bay with the new one. 
5.  Install all boards and connect all of the cables on the 6-slot bay. 
6.  Reload the 6-slot bay into the Charge Rack. 
Do not pinch wires during reinstallation as this may damage the equipment 
Be careful not to over-tighten the screws, which could damage the 6-Slot Bay and prevent 
the component from being adequately secured.