Troubleshooting 
8-2 
DIAD 6 Charge Rack Manual 
 
 
 
 
 
 
Symptoms 
Cause 
Suggested Action 
Terminal LED not illumi- 
nated on all 30 bays (all 
five banks). 
Charge rack is not receiving 
power 
Verify that the power cord is not dam- 
aged and is properly plugged into the 
rack and outlet. 
Verify the outlet has power.  Check the 
fuse or circuit breaker. 
If a power strip or surge protector is 
used, verify that it is turned on and 
functioning properly. 
Big harness failure/connec- 
tion issue 
Verify that the big harness is properly 
connected to the power supply.  If nec- 
essary, replace the big harness with kit 
part #200004056CNRKIT (see page 
). 
Power supply failure 
Replace the power supply with kit part 
#100008187CNRKIT (see page 
). 
Terminal fits loosely in a 
single bay. 
Terminal not seated properly 
Verify that the terminal is pressed firmly 
into the bay. 
Terminal LED begin flash- 
ing in the middle of 
charging. 
Terminal’s battery has 
stopped charging due to 
excessive heat or cold 
Allow the terminal to return to normal 
temperature, then retest.  It may be nec- 
essary to operate the rack in a tempera- 
ture-controlled environment. 
Terminal battery failure 
If charging does not resume after the 
terminal has returned to normal tem- 
perature, send the terminal in for repair. 
Defective terminal 
Send the terminal in for repair. 
Poor contact between connec- 
tor on distribution board to 
power supply cable 
If all 6 bays are flashing, remove the 6- 
bay module, add NyoGel 760 lubricant 
(see page 
).