Honeywell International Inc. IM11PRT Manuale Utente

Pagina di 44
IM11 RFID Reader Module Integration Guide (Confidential)
11
Read Current
1.3
A
Tx/Rx circuits, 
VCO, temperature 
sense
Ripple
100
mV
Peak-to-peak
Timing
Power on 
to Enable
Enable to 
Active
5
S
Only at initial 
power up
Standby to 
Active
1.5
2
mS
An internal time, 
not seen by the host
Channel 
Switching
30
μS
Tx on a channel to 
Tx on any other 
channel
Transmitter Specifications
Specification Minimum
Typical
Maximum Unit
Notes
Frequency 
Stability
-20
+20
PPM
Spurious 
Emissions - 
FCC
-55
-50
dBc
dBc
In band
Out of band
Spurious 
Emissions - 
ETSI
-54
dBm Out of band
Thermal 
Shutdown
85
°C
As measured by 
sensor on module
Thermal 
Recovery
75
°C
Transceiver Specifications
Specification
Values
Output Power Control
29.5 dBm. User adjustable in 1 dBm down to 
10.5 dBm. Tolerance drift from +0.5 to -0.7.
Power Supply Specifications (continued)
Specification Minimum
Typical
Maximum Unit
Notes