IM11 RFID Reader Module Integration Guide (Confidential)
Operating Modes
This illustration shows the module Overtemperature and Standard 
operating modes.
The module has a temperature sensor. If overtemperature is detected 
(nominally 85 °C), the module sends an overtemperature message. No 
RF output occurs until the temperature falls below the recovery 
threshold (nominally 75 °C).
Overtemperature Mode
Standard Mode
IM11 is in Idle mode.
IM11 receives
a request for a tag 
operation from an 
application.
Is the IM11 
temperature 
<85 °C?
The IM11's ability to return 
to normal status depends 
on the ability of the card to 
dissipate the heat.
The IM11 is designed to 
operate at 1 Watt of 
continuous power between 
-20 °C and +60 °C. These 
limits are not user 
programmable.
IM11 API returns
“Status=Normal"
 and data, if found.
Application checks reason
for failed status and returns 
overtemperature condition.
IM11 API returns 
"Status=Failed."
IM11 receives
a request for a tag 
operation from an 
application
No
No
Yes
Yes