Example #4:  What are the device’s settings for all Codabar selections?
Enter:
cbr?.
Response:
CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is 
set to 1, or on; 
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; 
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled; 
the Minimum Message Length (MIN) is set to 2 characters; 
the Maximum Message Length (MAX) is set to 60 characters; 
and the Default setting (DFT) has no value.  
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands.  
First, the scanner must be put in Manual/Serial Trigger Mode either by scanning 
the Manual/Serial Trigger Mode bar code (
).  Once the scanner is in serial trigger mode, 
the trigger is activated and deactivated by sending the following commands:
Activate:SYN T CR
Deactivate:SYN U CR
The scanner scans until a bar code has been read, until the deactivate com-
mand is sent, or until the serial time-out has been reached (see 
on page 3-4 for a description, and the serial command on 
).
Resetting the Standard Product Defaults
If you aren’t sure what programming options are in your scanner, or you’ve 
changed some options and want the factory settings restored, scan the 
Standard Product Default Settings bar code below.
The chart on the following pages lists the factory default settings for each of the 
menu commands (indicated by an asterisk (*) on the programming pages).
Standard Product Default Settings