Honeywell International Inc. 50052669 Manuale Utente

Pagina di 24
TL9160
3
Determine the location
The equipment interface module (EIM) consists of a relay and an antenna. They can be
installed either in the wiring compartment of the baseboard heater or in a 4”x4” junction
box.
NOTE: Install EIMs at a minimum distance of 2 feet (0.6 m) of each other. This minimum
distance still applies even if the EIMs are on opposite sides of a wall.
Installing the EIM in the baseboard heater
You can install the EIM in the wiring 
compartment of the heater if you have any of 
the heaters listed in the following table:
Install the EIM in a 4”x4” electrical box
Install the EIM in a 4”x4” electrical box:
• if you have a convector or fan-forced heater.
• if you cannot install or do not wish to install the
EIM in the wiring compartment of the heater.
NOTE: The electrical box can be installed anywhere 
in the house; for example, near the main electrical 
panel.
Install the Equipment Interface Module (EIM)
2.
Manufacturer / brand
Series
Cadet
F
Global Commander
CCB
King Electrical
K, CB, KP, M
Marley
2500, BKOC, QMKC
Ouellet
ODBA, ODI, ODIA, OFM, OPR
Stelpro
CBB, N, SCA, SCAS
TPI
2900C, 2900S, 3700, 3900
NOTE: The product has been tested for compatibility with the heaters listed above. If
your heater is not in the list, install the EIM on an electrical box or replace it with one
listed.
Relay
Antenna
Relay
Antenna
69-2474EFS (Honeywell YTL9160 System Installation Guide).book  Page 3  Friday, April 29, 2011  12:04 PM