Honeywell International Inc. CTU-K05 Manuale Utente

Pagina di 27
TemaServer TS TAx3    (CTU-K03 code 1500064FA)  
Page 17 
TECHNICAL SPECIFICATIONS 
TemaServer TS TAx3    
(CTU-K03 code 1500064FA) 
Parameter 
Value 
DC power supply 
12V
DC
±15% 500mA nominal (6W) 
600mA max (for fast battery recharge) 
AC power supply 
12V
AC
±15% 50Hz 
500mA (nominal) 
600mA max (for fast battery recharge) 
Power supply via TRN01 
Transformer 
230V
AC
 ±15% 50Hz 
30mA nominal (7VA) 
40mA max. (for fast battery recharge) 
Weight 
(including frame)
 
3.5kg (+ transformer TRN01 = 500g) 
Size 
220x305x80 mm 
IP Protection Rating 
IP55 
Environmental 
temperature for correct 
operation
 
0…50 °C 
LAN Ethernet 
connection 
10BaseT standard cable on RJ45 
Proxy antennae 
Double antenna 125KHz for HID cards 
Read distance 0…50mm 
Expansions 
2 slots for 1-unit plug-in cards  
(or une 2-units plug-in card) 
Relay outputs  
Number of outputs: 2  
Max. load allowed: 
 
50V
DC
 1A