Honeywell International Inc. T8665E Manuale Utente

Pagina di 52
25
69-1538
Heat Pump Fault Monitor LED lights red when 
heat pump failure is 
detected. Switch thermostat 
to Em. Ht. and contact you 
heat pump service com-
pany.  Heating with Em. Ht. 
is expensive, so act quickly.
Successful Communication Indicator
The thermostat periodically sends and receives 
messages. The small triangle right of the 
temperature display indicates the thermostat 
successfully communicated with the system 
controller installed by your Energy Utility.
PROGRAMMING YOUR 
THERMOSTAT
7-Day Program and Operation
Your thermostat is 7-day programmable, which 
means you can set your thermostat for four 
periods (Wake, Leave, Return and Sleep) and 
up to eight temperatures (four Heat and four 
Cool) for each day of the week. Each day can 
be the same or different.
M17763
Mon
System
Fan
Heat
Auto
AM
Heat
Temporary
HEAT PUMP